Features and Accessories
3 and 6 inch ground leads. Use the three- and
six-inch ground leads for general probing. The
socketed end of the leads may be connected to
any of the probe tips and adapters, or fitted onto
0.025 inch pins.
To attach the ground leads, press and rotate the
lead pin connector into the ground socket on the
probe head. The lead may be removed by simply
pulling the pin out by hand.
When selecting the grounding connection,
maintain as short a ground path as possible.
Refer to page 2- - 2 for more information.
Low-inductance ground lead. Use the
low-inductance ground adapter to substantially
reduce ground lead inductance. Because the
ground lead simply touches the ground reference,
you can easily move the probe to different points
on the device under test.
To attach, press the ground lead into the probe
head gound socket.
When selecting the grounding connection,
maintain as short a ground path as possible.
Refer to page 2- - 2 for more information.
Signal- Ground Adapter. The signal-ground
adapter is ideal for use with signal/ground pairs
on 0.100 inch header pins (such as FlexLead™
adapters).
Attach the signal-ground adapter by gently
pressing it into the ground socket on the probe
head.
Be sure to use the stabilization notch whenever
possible. See page 2- - 8 for further details.
FlexLead
Adapter
Signal Ground
Adapter