7.13 Connect the actuator distributor (L) to the actuator (A) of the electronic module (K).
7.14 Connect the electronic module (K) to the power supply.
Output
Actuator 1_1
Actuator 1_2
Temperature sensor 1 (for
direct temperature
recording with the
electronic module)
Digital sensor input (2)
(for indirectly recording
temperature via an
external switching
contact)
8.
Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and regulations
applicable on site, the fitting must be maintained and serviced at regular intervals.
Use suitable cleaning agents that are not harmful to the fittings in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
9.
Replacement Parts
Designation
Electronic module M1 . . . . . . . . . . . . 84-100-17.108
Surface sensor, red . . . . . . . . . . . . . . 84-100-17.158
6
Description
Switching output for the heater of the water
reservoir ("storage filling") not floating, max. load
24 V DC, 1 A
Switching output for message "Temperature
reached", default logic "0", when the set
temperature is reached logic "1", not floating, max.
load 24 V DC, 1 A
Cyclical measurement of water-reservoir
temperature
Connection for external temperature sensor (logical
input = 1 –> temperature reached) e. g. computer-
aided facility management via coupling relay or
immersion thermostat max. 20 m (1.5mm² Cu)
OrderNo.