SYNOPTIC PANEL

On/Off: by pressing this button for 3 seconds, the
system will switch on if off and vice-verca
Automatic / Manual: by pressing this button you
will switch from one mode to the other
Decrease: reduces the ventilation power in manual
mode (from 9 to 1)
Increase: increases the ventilation power in manual
mode (from 1 to 9)

OPERATION MODE

The forced ventilation system has two operation modes:
Automatic mode
To prevent moving cold air in the room, automatic ventilation
starts only when the temperature detected by the probe is higher
than 50°C.
Under this threshold, the display will show the letter "A", while,
once the fan has been activated, the display will show a graphic
animation.
The fan power can go from 11% to 99%, in proportion to the
temperature increase between 40°C - 220°C.
Manual mode
The manual mode allows you to set the desired ventilation power
from 1 to 9.
Below are the powers, as a percentage of the maximum, corre-
sponding to every single level:
V1: 11%
V2: 22%
V3: 33%
V4: 44%
V5: 55%
V6: 66%
V7: 77%
V8: 88%
V9: 99%
Under 40°C the fan will turn off, but when the temperature is
over 40°C again, the fan will reach its last power value.
At a temperature over 150°C, the power will remain at 99%.
NOTE
By turning the system off and then back on again, the last venti-
lation power will be stored in the memory.
INSTRUCTIONS FOR USE
- 20
Synoptic panel position
-