Stove goes
Flue gas temperature
out. "AlAr /
sensor is defective.
Sond / Fumi" is
The wiring to the flue
shown in the
gas sensor is loose.
display
Display shows
The stove has been
"Cool Fire"
switched off manually,
by the timer mode or the
save mode. The stove is
in cooling down phase.
Power failure
Display shows
The flue blower is defec-
"Alar fan fail"
tive or the printed circuit
board cannot measure its
speed.
Display shows
Occurs when 15 minutes
"ALAR/NO/
after start up the smoke
ACC"
temperature still too low.
Not enough pellets in the
fire chamber. Not enough
pellets in the pellet hop-
per.
Display shows
Temperature of fume
"Alar/hot
gases becomes too high.
fumi"
Should the stove overheat, a safety device will engage and block the feeder me-
chanism. After the stove's cool-down cycle has been completed, re-engage the
thermostat placed at the back of the stove, by removing the thermostat's cap and
pressing the button underneath. In case of repeated malfunctions, please contact
authorized technical support. (see fig 16+17)
Replace the sensor. Only to be done by a
Qlima-approved technician
Fix the wiring. Only to be done by a Qlima-
approved technician
This is not an error; the cooling down
phase stops automatically when the stove
has cooled down sufficiently.
After the electricity supply has been re-
stored, the stove will start in the cooling
down phase. The stove can then be started
up again.
Either the flue blower, the printed circuit
board or the speed sensor is defective, or
the wiring is damaged or loose. Fix the de-
fect. Only to be done by a Qlima-approved
technician
Press on/off button to reset alarm. Wait
until unit is cooled down completely.
Clean fire chamber and brazier. Fill pellet
hopper. Start up with a new switching on
cycle.
Reset the heater and restart it.
In case of recurring problems, please con-
tact a Qlima approved technician.