11

Technical data

11.1

General data

Voltage variant:
Current variant:
Type
Design
Mounting position
Medium
Working pressure
Protection class
Permissible
1)
temperature range
Permissible supply
voltage
Power consumption
(at U
=DC 30 V)
vmax
CE marking (see declar­
2)
ation of conformity)
è www.festo.com/sp
– Max. cable length
Linearity
Electrical connection
Resolution of the
actual value output
Safety position
1) With an ambient temperature of T > 40 °C and an output pressure p2 8 bar, a forced convection (forced cooling) of the magnet is
1/8-10-....
required for the MPPES-
2) The device is intended for use in an industrial environment. Outside of industrial environments, e.g. in commercial and mixed-res­
idential areas, actions to suppress interference may have to be taken.
3) Only when using connecting cable from Festo.
Tab. 6
Festo – MPPES – 1501e English
MPPES-...-010
(Setpoint value: DC 0 ... 10 V)
MPPES-...-420
(Setpoint value: 4 ... 20 mA)
MPPES
Proportional pressure regulator
Any, preferably vertical (proportional solenoid upward)
Compressed air to ISO 8573-1:2010 [7:4:4];
Inert gases
Lubricated operation possible (required during subsequent operation)
Constant (independent of fluctuations in the compressed air supply) supply
pressure min. 1 bar higher than max. output pressure
IP65 in combination with plug socket according to accessories
Ambient:
0 ... +50 °C
Storage:
–20 ... +70 °C
Medium:
0 ... +60 °C
DC +18 ... max. 30 V (nominal value: DC +24 V)
Max. 20 W (at MPPES-2-... and at MPPES-6-...)
max. 30 W (at MPPES-10-...)
In accordance with EU EMC Directive
30 m
0.5 % full scale
Pin contact, 8-pin according to DIN 45326
8 bit (approx. 40 mV for voltage variant/approx. 0.0625 mA with current
variant)
If the supply voltage cable or the setpoint cable is broken, output pressure
goes back to 0 bar
3)