4.7
Adapting/installing the upper section
▶ Check the remaining difference in height between the upper edge of the floor
and the drain body or pump connector again. Take the height of any planned
floor covering into account. When screed is laid, care must be taken to slope the
screed in the direction of the drain.
▶ Shorten the upper section so that the difference in height determined + mini-
mum overlap (47 mm) is guaranteed. To check this, mark the minimum overlap
on the upper section after shortening and then fit the upper section in place.
The mark should be at the same height as the upper edge of the tank.
L The contour line on the upper section shows maximum shortening. If maximum
shortening is exceeded or minimum overlap is not observed, the tightness of
the tank is not guaranteed.
▶ Fit the upper section (take the contact points into account) and align. Up to 5°
angle of inclination is permissible.
016-083_02
Installation and operating manual
Fig. [11]
max. 5°
Fig. [12]