_CDF-11.book Seite 26 Freitag, 24. September 2010 1:57 13
Operation
Note
I
When switched off by the battery monitor due to low voltage the dis-
play (fig. 2 5, page 2) goes blank and the "POWER" LED
(fig. 2 2, page 2) flashes orange.
Caution – Danger of damage!
a
When switched off by the battery monitor, the battery will no longer
be fully charged. Avoid starting repeatedly or operating current
consumers without longer charging phases. Ensure that the battery
is recharged.
In "HIGH" mode, the battery monitor responds faster than at the levels "LOW"
and "MED" (see the following table).
Battery monitor mode
Switch-off voltage at 12 V
Restart voltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
This is how to select the battery monitor mode:
➤ Switch on the cooler.
➤ Press the "SET" button (fig. 2 4, page 2) three times.
➤ Use the "+" (fig. 2 6, page 2) and "–" (fig. 2 7, page 2) buttons to select
the battery monitor mode.
✓ The selected mode then appears in the display for a few seconds. The
display flashes several times before it returns to the current temperature.
Note
I
When the cooler is supplied by the starter battery, select the battery
monitor mode "HIGH". If the cooler is connected to a supply battery,
the battery monitor mode "LOW" will suffice.
If you wish to operate the cooler from the AC mains, set the battery
monitor to the "LOW" position.
26
BordBar CDF-11
LOW
MED
HIGH
10.1 V
11.4 V
11.8 V
11.1 V
12.2 V
12.6 V
21.5 V
24.1 V
24.6 V
23.0 V
25.3 V
26.2 V