Technical specifications

Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculated flow rate:
Flushing flow:
Flush water volumes:
Flush time:
Operating voltage:
Power consumption:
Switching output:
Protection class:
7.

Scope of delivery

Pos.
Quantit
1
2
3
4
5
6
7
8
9
x
Name
y
1
Radar sensor
1
Siphon
1
Power pack for control unit
1
Control unit
2
Seals
1
Solenoid valve
1
Connecting piece
1
Urinal connector
1
G3/4 hose connection and outlet bend
1
Installation and operating instructions
1.0 bar
1-5 bar
10 bar
0.3 l/s
0.3-0.7 l/s
Adjustable from 1.2-10.5 l/s
Adjustable from 4-15 seconds
230 V AC
0.5 VA
Bistable RPE solenoid valve 6 V
Solenoid valve IP40
Power supply unit IP65
Radar sensor IP 65
Control unit IP55