Télécharger Imprimer la page

Output Configuration - Balluff IO-Link BMF 415KW-HA W-5 Série Notice D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 53
BMF 415KW-HA _ _ _ -W-5- _ _ -...
Magnetic Field Sensors
6
IO-Link interface (continued)
6.5
Parameter data
Index
Subindex
FSS (Fixed Switching Signal)
0x0039 (57)
0
Device Configuration
0x00B4 (180)
0
0x00F8 (248)
0,1,2
0x0420 (1056)
0
Condition Monitoring
0x0052 (82)
0,1,2,3,4,5
0x0053 (83)
0,1,2
0x0057 (87)
0,1,2,3
0x0058 (88)
0
System parameters
0x0003 (3)
0, 1, 2, 3, 4, 5 Data Storage (see section 6.5.9)
0x000C (12)
0
0x000D (13)
0, 1, 2
0x000E (14)
0
Tab. 6-5:
Parameter data of IO-Link interface
6.5.1
FSS (Fixed Switching Signal)
Index
Subindex
FSS 0x0039 (57)
Tab. 6-6:
Parameter Fixed Switching Signal
6.5.2

Output configuration

Index
Subindex
Output Type
0x00B4 (180)
Tab. 6-7:
Parameter output configuration
Yellow LED
Sensor
frontend
FSS Logic:
0 = high active
1 = low active
Fig. 6-1:
Illustration of the output circuit
14
english
Parameter
FSS Logic (see section 6.5.1)
Output Type (see section 6.5.2)
Diagnosis Suppression Configuration
(see section 6.5.4)
Disturbance Suppression Duration
(see section 6.5.3)
Device Temperature (see section 6.5.5)
Temperature Thresholds (see section 6.5.6)
Operating Hours (see section 6.5.7)
Boot Cycle Counter (see section 6.5.8)
Device Access Locks (see section 6.5.10)
ProfileCharacteristic (see section 6.5.11)
PD Input Descriptor (see section 6.5.12)
Name
0
FSS Logic
Name
0
Switching output Out 1
Process Data
PD
Out 1
Size
Access
1 byte
Read/Write
1 byte
Read/Write
2 bytes
Read/Write
2 bytes
Read/Write
10 bytes
Read Only
4 bytes
Read/Write
12 bytes
Read Only
4 bytes
Read Only
39 bytes
Read/Write
2 bytes
Read/Write
4 bytes
Read Only
3 bytes
Read Only
Size
Access
1 byte
Read/Write
Size
Access
1 byte
Read/Write
Data storage
X
X
X
X
X
X
Values
0 = high active
1 = low active
Values
0 = Deactivated
1 = PNP (default)
2 = NPN
3 = Push-Pull

Publicité

loading