BMF 415KW-HA _ _ _ -W-5- _ _ -...
Magnetic Field Sensors
6

IO-Link interface

This section is only relevant for the IO-Link
versions (BMF 415KW-HAKKI-...).
6.1

Communication parameters

In Tab. 6-1 the basic IO-Link specification is described.
Specification
Transfer rate
Minimum cycle time of device
Frame specification:
– Amount of preoperate data required
– Amount of operate data required
– ISDU
IO-Link protocol version
Amount of process data from the device to the master
Amount of process data from the master to the device
Manufacturer ID
Device identification
IO-Link profile
IO-Link profile type
Tab. 6-1:
Device Specification BMF 415KW-HAKKI-...
The minimum cycle time (MinCycleTime) of the
BMF 415KW-HAKKI-... is 2.3 ms.
If needed the master can increase the cycle
time, which is why the actual used cycle time
(MasterCycleTime) depends on the IO-Link
master.
6.2
Process data (PD)
The BMF 415KW-HAKKI-... cyclically outputs the state of
the switching point over the IO-Link interface. It is also
determined whether the magnetic field is strong enough to
ensure reliable switching over the entire temperature range
of the sensor.
If the assured switching field strength was reached when
setting the switching point, it can be assumed that the
sensor will switch reliably over the entire temperature
range.
12
english
IO-Link description
COM2
MinCycleTime
M-sequence capability:
– Preoperate M-sequence type
– Operate M-sequence type
– ISDU supported
Revision ID
ProcessDataIn
ProcessDataOut
Vendor ID
Device ID
Profile
Profile Type
Bit
Name
7
6
5
4
3
2
Assured switching field
1
strength
0
Fixed switching signal
Tab. 6-2:
Process data
Value
38.4 kBit/s
2.3 ms (0x17)
0x11
2 bytes
1 byte
Supported
0x11 (Version 1.1)
2-bit / SIO mode
supported (0x42)
0 bits (0x00)
0x0378
0x080201
Smart Sensor Profile Ed 2
(Fixed Switching Sensor)
SSP1.1
Information
Assured switching field
strength reached
Switching point reached

Publicité