8. Technical data

Max. operating
pressure
Permissible operating
temperature
Number of outlets
Max length of pipes
Output of pump
element
Reservoir capacity
Greases
Weight
(max depending
on outlets)
System of protection
Electrical
specifications
Rated voltage
Typ. power input
at 20°C (68°F) and
max. Operating
pressure
32
LAGD 1000/DC
150 bars (2 175 psi)
-25°C/+75°C
(-13°F/+167°F)
10 to 20
6 metres (20ft)
2 cm
/min
3
(0.122 in
/min)
3
1 l (61 in
)
3
up to NLGI grade 2
3,7 kg (8.2 lbs)
IP65
24 V DC
0,5 A
LAGD 1000/AC
150 bars (2 175 psi)
-25°C/+60°C
(-13°F/+140°F)
10 to 20
6 metres (20ft)
2 cm
/min
3
(0.122 in
/min)
3
1 l (61 in
)
3
up to NLGI grade 2
4,8 kg (10.6 lbs)
IP65
115 V / 50 Hz; 115 V / 60 Hz
230 V / 50 Hz; 230 V / 60 Hz
115V: 1 A / 50 Hz;
1.3 A /60 Hz
230V: 0.45 A / 50 Hz;
0.66 A / 60 Hz