Designation

LAGD 1000/DC10

LAGD 1000/DC12
LAGD 1000/DC14
LAGD 1000/DC16
LAGD 1000/DC18
LAGD 1000/DC20
Using the calculated example shown in section 3. If the LAGD 1000/DC10 was to be used,
then the contact time (tCO) should be set to 1,0 minutes (meaning that all outlets receive
0,2 cm
). The tPA should be set to 4,4 hours.
3

4.3.2 Procedure voor het programmeren van de LAGD 1000/AC en

LAGD 1000/DC
The table below shows the sequence of how to program the unit.
Step
Key
1
Press for more
than 2s
2
Press briefly
(confirm code)
3
Press briefly
SKF LAGD 1000
Number of outlets
10
12
14
16
18
20
Display
Running time (tCo) for one
internal cycle of progressive
feeder giving 0,2 cm
(minutes)
1,0
1,2
1,4
1,6
1,8
2,0
000 in display flashes
Automatically indicates first parameter
Example: "Pause in timer operation"
LED "Pause" flashes
Pause time 1 h (factory setting).
Values between 0,1 and 99,9 hrs,
should be a minimum of :
• LAGD 1000/AC 4 x pump running
time (tCO) in hours. eg. if tCO =
5 minutes, tPA=0,4 hours minimum
• LAGD 1000/DC 9x pump running
time (tCO) in hours. eg. if tCO =
5 minutes, tPA=0,8 hours minimum
/outlet