4.

Important Notes

• Installation, commissioning and maintenance are to be performed only by a
qualified technician according to the instructions provided and in accordance with
legal requirements and acknowledged rules of technology.
• All technical connection regulations specified by the local water and electricity
supply utility companies must be complied with.
• All rights reserved to make technical alterations.
5.

Application

PROTRONIC - non-touch, opto-electronically controlled WC flush valve DN 20 in
combined assembly design for concealed mounting. For connecting to cold water
supply. Flushing duration adjustable down to the second.
6.

Technical Specifications

Minimum flow pressure:
Recommended flow pressure:
Maximum operating pressure:
Calculation flow rate:
Flushing flow rate:
Flush water volume:
Operating voltage:
Power consumption:
Type of protection:
7.

Dimensions

8.

Assembly Instructions

Warning!
• Operate the product only with safety extra low voltage (SELV). Do not earth the
components.
• The power supply (to be provided by the customer) must be set up outside of the
wet area, in a separate room.
• Secure the electric connection with an earth leakage circuit breaker (RCD).
Failure to observe can mean risk of death or material damage, e.g. from electric
shock or fire.
1.0 bar
1.2–4 bar
10 bar
1.0 l/s
1.0–1.3 l/s
6–9 l adjustable
24 V DC
3.5 W
IP 68