Télécharger Imprimer la page

The Refrigerator - GE GTH21 Série Manuel D'utilisation Et D'installation

Publicité

Les langues disponibles

Les langues disponibles

INSTALLING THE WATER LINE (cont.)
TIGHTEN THE PIPE CLAMP
5
Tighten the clamp screws until the sealing
washer begins to swell.
NOTE: Do not overtighten or you may crush the
tubing.
Pipe Clamp
Clamp
Screw
ROUTE THE TUBING
6
Route the tubing between the cold water line and

the refrigerator.

Route the tubing through a hole drilled in the wall
or floor (behind the refrigerator or adjacent base
cabinet) as close to the wall as possible.
NOTE: Be sure there is sufficient extra tubing
(about 8 feet [244 cm] coiled into 3 turns of about
10" [25 cm] diameter) to allow the refrigerator to
move out from the wall after installation.
7
CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve)
for copper tubing onto the end of the tubing and
connect it to the shutoff valve.
Make sure the tubing is fully inserted into the
valve. Tighten the compression nut securely.
For plastic tubing from a GE SmartConnect
Refrigerator Tubing kit, insert the molded end
of the tubing into the shutoff valve and tighten
compression nut until it is hand tight, then tighten
one additional turn with a wrench. Overtightening
may cause leaks.
Saddle-Type
Shutoff Valve
Packing Nut
Outlet Valve
Installation Instructions
Washer
Inlet End
Compression Nut
SmartConnect
Ferrule (sleeve)
8
FLUSH OUT THE TUBING
Turn the main water supply on and flush out the
tubing until the water is clear.
Shut the water off at the water valve after about
one quart (1 liter) of water has been flushed
through the tubing.
CONNECT THE TUBING TO THE
9
REFRIGERATOR
NOTES:
be sure the refrigerator power cord is not
plugged into the wall outlet .
we recommend installing one if your water
supply has sand or particles that could clog the
screen of the refrigerator's water valve. Install
it in the water line near the refrigerator. GE
SmartConnect™ Refrigerator Tubing kit , you
will need an additional tube (WX08X10002) to
connect the filter. Do not cut plastic tube to
install filter.
Remove the plastic flexible cap from the water
valve (refrigerator connection).
Tubing
19

Publicité