7.2.10 Menu "VIEW SETTINGS"
In this menu you can verify the parameters set in the motherboard, without having the possibility to change them.Such settings can be adjusted
by authorized techician only.
Start
Flame light
Fire Pot cleaning
OFF
To enter in the USER MENU press two times key OK.
To enter in the menu "VIEW SETTINGS" press 9 times key 2. By confirming with OK you enter in the list of set parameters. To scroll the list of
parameters use key 1 and 2.You can view such settings by pressing "OK" key.
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
7.2.11. Menu "VIEW WORKING HOURS"
In the menu VIEW WORKING HOURS you can check the total or partial working hours and also the number of ignitions of the stove has made.
It is possible sometimes that the working hours are not reset and you see numbers like 5000/15000/25000. It will be care of the technician to
reset these numbers by first ignition. This does not means that the stove has already worked for so many hours, it is just a setting made during
the tests we make in Ravelli, before the stoves are packed and delivered. This menu is used by the After Sales Center to evaluate the total
working hours of the stove during the season and consequently to evaluate the need of cleaning ("service hours").
Counter total
hours
To enter in the USER MENU press two times key OK.
To enter in the menu "VIEW WORKING HOURS" press 10 times key 2. By confirming with OK you see the working hours of the stove. To scroll
the different counters (total or partial hours and number of ignitions) use key 1 and 2.
To return to the main screen press at the same time keys 1 and 2.
Alternatively it is possible to exit by step from the menus by pressing each time the key OK.
7.2.12 Menu "SET AIR/PELLET"
The set of the draught-pellet blend allow to modify immediately the quantity of inlet air and the quantity of pellet loaded in the firepot.
The stove is tested with pellet certified DIN PLUS. If you do not use certified pellet could be necessary to set the combustion. Normally
the modification is made on the "% FLUX" to adjust the inlet air and consequently the combustion; if the regulation of the flux is not
sufficient could be necessary to adjust also the "% PELLET".
User and maintenance manual for stoves with RDS technology
Flow
01/02/2016
Pag.27