SALT CHLORINATOR

7.3. INSTALLING THE ACCESSORIES HOLDER

1) Remove the 5 stoppers and 2 reducers from the
accessories holder.
2) Following the image and instructions shown
opposite, install the accessories holder with or
without the 2 reducers (depending on the diameter
of the pipe).
3) Depending on the elements to be connected to the
accessories holder, screw back up and tighten by
hand the plug(s) required in the accessory holder,
using sealing tape (not supplied).
12
WWW.NORSUP.EU
7.4. INSTALLING THE SALT/TEMPERATURE/
LOW-WATER SENSOR
Screw and tighten by hand the salt/temperature/
water shortage sensor
4
in the accessories holder
15
without using sealing tape.

7.5. INSTALLING THE POOL GROUND (OPTIONAL)

The Pool Ground is intended for functional and not
safety purposes. It enables static electricity, whatever
its source may be, to be transferred from the pool
water to the ground. In some cases, static electricity
can stimulate the oxidation of metal parts in contact
with pool water. Static electricity can also disturb the
working of probes, which can lead to the equipment
as a whole not working correctly.
1) Without applying Teflon tape, screw in and tighten
14
the Pool Ground by hand
into the accessories
15
holder
.
14
2) Connect the pool earthing device
to a ground
rod
11
(not supplied) using a copper cable without
3
isolating sleeve
(not supplied).
11
3) Insert the whole ground rod
into the ground.
ATTENTION
• You must comply with the specifications of
installation standards in the country and at the time
of the installation.
• The ground rod should be sited at a distance and
unaffected by any other electrical ground device/rod.
• The ground rod must be at least 1.5 m long.
• The ground into which the ground rod is inserted
should be as wet as possible, and have a resistance
of less than 20 Ω.
Alterations which serve the technological progress as well as errors excepted!
SALT CHLORINATOR
7.6. INSTALLING THE PH INJECTION HEAT
CONTACTOR (MODELS DUO AND PRO)
,
1) Place the pH corrector container
possible to the equipment room's internal
ventilation and as far away as possible from any
electrical device.
10
2) Connect the ballasted filter
13
pump
, with the semiflexible tubing
A
to the right size (see photos
10
3) Insert the ballasted filter
at the bottom of
container
2
.
4) With the use of Teflon tape (not supplied), screw
18
the injection connector
into the accessories
holder
15
and tighten by hand.
ATTENTION
Following image
C
(exploded view of the injection
18
connector
), respect the direction of assembly of
the parts, and in particular the direction of the arrow
engraved on the fitting. Failure to follow these
instructions can lead to the peristaltic pump being
damaged.
5) Connect the injection connector
13
pump
, with the semi-flexible tubing,
as needed.
Alterations which serve the technological progress as well as errors excepted!
7.7. I NSTALLING THE PH PROBE (MODELS DUO AND
PRO)
ATTENTION
The life of the pH probe depends primarily on the
strict observance of all the instructions provided in
this manual.
1) Check that the probe bulb is properly immersed in
the solution inside the storage vial.
If this is not the case:
a) Remove the storage vial from the probe (see
photo below), and keep it for wintering.
b) Rinse the bulb with tap water.
c) Soak the probe for 30 minutes in tap water or
2
as close as
in a suitable KCl solution (saturated potassium
chloride).
d) Move directly to stage 3).
2) Remove the storage vial from the probe, and keep
to the peristaltic
it for wintering.
21
to be cut
B
and
).
ATTENTION
Never touch the bulb of the probe.
18
to the peristaltic
21
to be cut
EN
DE
FR
ES
PT
IT
ORIGINAL MANUAL NORSUP
13