SALT CHLORINATOR

15.2. CELL

The auto-clean function helps prevent scale deposits
on the cell. However, if scale builds up despite this,
carry out manual cleaning:
1) Turn off the equipment, remove the cell (or electrode)
and check for signs of scale.
2) Use a suitable cleaning product to remove the scale.
Connections outside
the cleaning product
Cleaning product
Titanium plates
fully submerged
In-line cell
T cell electrode
3) Rinse and then reassemble the cell (or electrode).
4) Readjust if necessary the inversion frequency (see
the „Inversion Electrolysis" menu in chapter 11).
ATTENTION
• The service life of the electrolytic cell is very
closely related to observance of the instructions
and information contained in this manual.
• The replacement of a cell at the end of its life with
a compatible cell may lead to a decrease in
production and reduce the life of the equipment.
It is therefore strongly recommended to use only
an original manufacturer cell.
• Damage due to the use of a compatible cell voids
the contractual guarantee.

15.3. PH PROBE AND ORP PROBE

→ Periodic maintenance to be carried out:
- twice/year,
- each time the equipment is put back into service,
- each time the probe is changed.
Carry out a calibration of the probe.

15.4. PH INJECTION HEAT CONTACTOR

→ Periodic maintenance to be carried out: - once/year.
→ To replace the parts below, you will need a
maintenance kit.
1) Change the hose inside the peristaltic pump (see
arrow below).
30
WWW.NORSUP.EU
2) Change the non-return valve on the injection
connector.
ATTENTION
Ensure the above parts are assembled the right
way round, paying particular attention to the
direction of the arrow marked on the fitting.
Failure to follow these instructions can lead to the
peristaltic pump being damaged.

16. FAULTS, DIAGNOSIS AND TROUBLESHOOTING

ATTENTION
• The set of operations described in chapter 16
presents some risks. These operations must be
carried out by persons with the required training
and authorisation.
• Comply with all the safety instructions presented
in chapter 2.
→ Any alarm triggered:
• will immediately be displayed on the screen.
• can be manually cleared by pressing button .
• can be disabled (except
"A4 alarms - Cell
Power"),
by disabling the function of the sensor related to
the fault detected (see the
„Sensor
Settings" menu
in chapter 11).
→ The
„pH calibration
alarms" and
alarms" automatically and
AL - pH regulation
immediately stop the pH regulation.
→ The alarms "A1" to "A4" automatically and
immediately stop chlorine production.
Alterations which serve the technological progress as well as errors excepted!
SALT CHLORINATOR
Alterations which serve the technological progress as well as errors excepted!
EN
DE
FR
ES
PT
IT
ORIGINAL MANUAL NORSUP
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

DuoPro

Table des Matières