1 About this documentation

These instructions contain important information for the safe and appropriate as-
sembly and commissioning of the product.
Read these instructions carefully, especially chapter g 2. Safety instructions
u
before you start working with the product.

1.1 Additional documentation

1. Also follow the instructions for the other system components.
2. Please also observe the generally relevant, statutory, and other binding regu-
lations of European and national legislation and the national regulations for
accident prevention and environmental protection in your country.

1.2 Presentation of information

1.2.1 Warnings

In this documentation, there are warning notes before the steps whenever there
is a risk of personal injury or damage to equipment. The measures described to
avoid these hazards must be followed.
Structure of warnings
Hazard type and source
Consequences of non-observance
Precautions
u
Meaning of the signal words
Possible dangerous situation.
Failure to observe these notices may result in minor injuries or damage to
property.

1.2.2 Symbols

Recommendation for the optimum use of our products.
Observe this information to ensure the smoothest possible operation.

2 Safety instructions

The product has been manufactured according to the accepted rules of current
technology. Even so, there is a risk of injury or damage if the following general
safety instructions and the specific warnings given in this instruction manual are
not observed.
1. Please read all these instructions carefully before working with the product.
2. Keep these instructions in a location where they are accessible to all users at
all times.
3. Always include the operating instructions when you pass the product on to
third parties.

2.1 Intended use

The product is exclusively intended for installation in a machine or system, or for
combination with other components to form a machine or system. The product
may only be commissioned after it has been installed in the machine/system for
which it is intended.
Use is permitted only under the operating conditions and within the performance
limits listed in the technical data. Only use compressed air as the medium.
The product is technical equipment and is intended for professional use only.
Intended use includes having fully read and understood these instructions, espe-
cially chapter g 2. Safety instructions.

2.2 Personnel qualifications

All tasks associated with the product require basic mechanical, pneumatic, and
electrical knowledge, as well as knowledge of the respective technical terms. In
order to ensure operational safety, these tasks may only be carried out by quali-
fied personnel or an instructed person under the direction of qualified personnel.
AVENTICS™ NL1 | NL2 | NL4 | NL6 | R412015556-BAL-001-AE | English
SIGNAL WORD
CAUTION
Qualified personnel are those who can recognize possible dangers and institute
the appropriate safety measures, due to their professional training, knowledge,
and experience, as well as their understanding of the relevant regulations per-
taining to the work to be done. Qualified personnel must observe the rules rele-
vant to the subject area.

2.3 General safety instructions

• Observe the valid local regulations to protect the environment in the country
of use and to avoid workplace accidents.
• Only use AVENTICS products that are in perfect working order.
• Check the product for obvious defects, such as cracks in the housing or miss-
ing screws, caps, or seals.
• Do not modify or convert the product.
• Persons who assemble, operate, disassemble, or maintain AVENTICS products
must not consume any alcohol, drugs, or pharmaceuticals that may affect
their ability to respond.
• The warranty will not apply if the product is incorrectly assembled.
• Do not place any improper mechanical loads on the product under any cir-
cumstances.
• Product warnings and information must be legible, i.e. not covered by paint,
etc.

2.4 Safety instructions related to the product and technology

• Lay cables and lines so that they cannot be damaged and no one can trip over
them.
• Do not operate the product in aggressive ambient air or allow it to come into
contact with aggressive media.
The substances listed as examples in the following table, which contain sol-
vents in various concentrations, can lead to an aggressive ambient air/com-
pressed air in the application area of compressed air preparation devices and
in the suction area of air compressors.
Solvents:
Acetone, paint thinners, alcohols, ester
Detergents:
Trichloroethylene, perchlorethylene, benzene, gasoline
Other media:
Synthetic oils, drilling oil, high-alloyed oils, certain compres-
sor oils, brake fluid, ammonia, bonding and sealing agents,
plasticizers, anti-freeze, coolants/lubricants
• A pressurized polycarbonate reservoir may corrode in an aggressive ambient
air/compressed air and explode as a result.
If the presence of the substances stated in the table cannot be avoided, such
as in gluing machines or vulcanization plants, the use of metal reservoirs is re-
quired.
• If a lubricator is used, please only use a suitable pneumatic oil, see online cata-
log (www.aventics.com/pneumatics-catalog).
• No soiling may be allowed to collect on or in the filters, reservoirs, or win-
dows. Replace reservoirs if soiling cannot be removed from the drain (drain
may become clogged).
Also observe the "Customer information on material resistance in
compressed air preparation" (MNR R412025273)

3 Scope of delivery

• 1x filter (standard, pre, micro, active carbon filter) as ordered
• 1 set of operating instructions

4 About this product

Standard filter FLS, pre-filter FLP, micro-filter FLC, and active carbon filter FLA are
components of air preparation units:
• Standard filter FLS: Solid impurities and condensate are removed from the
compressed air by centrifugal force and filtration.
• Pre-filter FLP and micro-filter FLC: Suitable for very high standards in com-
pressed air purity.
• Active carbon filter FLA: Filters out odors from the compressed air. The oil va-
por molecules in the compressed air are absorbed.
10