LOAD DATA PROGRAM

PROGRAM SELECT
LOAD DATA
LOAD [01] NiMH
14.4V
3000mAh
Load...
BATTERY METER TESTING
PROGRAM SELECT
LI BATT METER
Measuring VOL
WAIT PLEASE...
3.88
3.88
3.84
0.00
0.00
0.00
MAIN 11.6V
H3.885V L3.837V
MEASURE INTERNAL RESISTANCE PROGRAM PER CELL
In this program, the charger cannot only measure the internal resistance of the battery pack, and also
can measure the per-cell internal resistance (only available for lithium battery). Plug the balance wire only.
Test LiXX Inter-
nal Resistance
Measuring IR
WAIT PLEASE...
1:001 001 001 mΩ
4:001 ---
---
mΩ
Battery Pack IR
4mΩ
This program calls back the data that was stored at "Save Data" program.
To load the data, press Start/Enter key once to blink the data number field
and select the number using INC or DEC key then press Start/Enter key for
more than 3 seconds.
Select the data number to be called back.
The data matched with the number will be displayed at this time.
Loading the data.
Battery Meter testing can be a very valuable tool for battery diagnostics. To
proerly use the battery meter, you must connect both the charge wire and the
balance wire to the charger.
To begin, press Start/Enter button. The charger will provide the results in the
form of a voltage reading. Press increase to check the total result of the pack.
Press increase again to return to the single cell data.
Press « Start » : The battery pack start to measure internal resistance per cell.
The two lines shows the first of the sixth cell's internal resistance, which is
only available for the lithium battery. Press "DEC" or "INC" to display more
information.
This screen displays the battery pack internal resistance. Press "DEC" or
"INC" to display the status information.