Télécharger Imprimer la page

Dräger Panorama Nova P - sideport - RA Mode D'emploi page 4

Masque complet avec raccordement p à encliqueter fiches

Publicité

Les langues disponibles

Les langues disponibles

Panorama Nova P - sideport – RA
Full face mask with plug connection
For Your Safety
Strictly follow the instructions for use: Any use of the full face mask
requires full understanding and strict observation of these instructions. The
full face mask is only to be used for the purposes specified.
Maintenance: The full face mask must be inspected and serviced by
experts at regular intervals and a record kept. Repair and general overhaul
of the full face mask may only be carried out by trained service personnel.
We recommend signing a service contract with Dräger Safety to have all
maintenance jobs carried out. Only authentic Dräger spare parts may be
used for maintenance. Observe chapter "Maintenance Intervals".
Accessories: Only use accessories listed in the order list.
Liability for proper function or damage: The liability for the proper func-
tion of the full face mask is irrevocably transferred to the owner or operator
to the extent that the full face mask is serviced or repaired by personnel not
employed or authorized by Dräger Safety or if the full face mask is used in a
manner not conforming to its intended use. Dräger Safety cannot be held
responsible for damage caused by non-compliance with the recommenda-
tions given above. The warranty and liability provisions of the terms of sale
and delivery of Dräger Safety are likewise not modified by the recommen-
dations given above.
Dräger Safety AG & Co. KGaA
Markings
These Instructions for Use apply to masks with the following type identity
markings:
Panorama Nova – EPDM – PC – P – sideport – RA
The identification marking is externally legible: Panorama Nova and EPDM
on the mask body. PC on the lens. P on the facepiece connector. Mask
body with EN 136.
CE marking with ID-No. 0158, EN 136 Cl. 3.
A round thread connection is located at the left hand side of the mask.
What is what?
12
6
5
4
3
2
9
1
11
10
1
Facepiece connector 6
Lens frame
2
Button
7
Head strap
3
Nose cup valve
8
Sealing frame
4
Inner mask
9
Mask body
5
Lens
10 Connector clamp
Description/Intended Use
The listed full face masks are masks according to EN 136 Cl. 3 and carry
the CE and class mark. The masks protect face and eyes against aggres-
sive substances. Special goggles are available for users who wear specta-
cles. Ambient air temperature –30
pressure fresh air hose breathing apparatus according to EN 139, e.g.
ABIL-L-3 (AL 012 69) with LA Plus A and filter, only use certified breathing
protection apparatus!
4
7
8
13
11 Exhalation valve cover
12 Front strap
13 Round thread con-
nection according to
EN 148-1
o
o
C to 120
C. Only use with positive
Use
Keep the full face mask ready: Undo the head strap as far as possible.
Pass the carrying strap around your neck and button it into the front strap.
Fasten full face mask: Facial hair under the
mask seal can cause leaks! The full face mask
should not be used by people with beards and
sideburns. The bow of glasses under the
mask seal also causes leaks. A spectacle
frame should be used in such cases. Unbut-
ton the carrying strap. Place chin in recess.
Pull the head strap kit over the head and draw
backwards until the headband fits smoothly.
Adjust the full face mask.
1 Stretch the neckbands evenly.
2 Stretch the temple straps evenly.
3 In case of small head shape, also stretch the
headband.
4 Remove the filter plug. Screw the breathing
filter provided for use into the round thread
connection (as the breathing filter will only be used for a short period of
time, choose its capacity accordingly). Prior to use, read the instructions
for use of the compressed air hose breathing apparatus. If, during the use
of compressed air hose breathing apparatus, uncoupling is required
(change of work place), the breathable air is temporarily supplied via the
breathing filter. (In this case, the breathing resistance required according
to EN 148-1 is perhaps not reached.) Prerequisite for this is the breatha-
ble air supply hose to be uncoupled at the distributor piece (basic set)
and the check valve to be flush in the distributor piece (basic set). Sepa-
ration of the lung demand valve (LDV) from the full face mask is not
allowed.
Carry out leak test: Press the button and insert the lung demand valve
into the facepiece connector. Release the button and check whether the
lung demand valve has locked into place. Close the plug-in nipple at the
medium pressure hose with your thumb. Seal the filter opening with the
heel of your hand. Breathe in until a negative pressure is produced. Briefly
hold your breath: the vacuum must be maintained. If it is not, the straps
must be tightened further. The leak test must be repeated twice. Report to
operation only with an airtight full face mask!
Check the exhalation valve: Seal the plug-in nipple and exhale vigour-
ously. The exhaled air must escape easily, otherwise see "Visual inspection
of exhalation valve".
Connect the positive pressure fresh air hose breathing apparatus
Extreme operating conditions
In case of low temperatures: Treat lens with antimisting agent "klar-pilot"
gel to prevent it from fogging up.
In case of high temperatures: Leave the danger zone immediately if lens
is damaged.
In case of chemicals: Some substances, e.g. H
absorbed by the material of the full face mask, especially silicon, and may
possibly diffuse into it.
In explosion-hazard area: Treat the full face mask with antistatic spray or
work with a screen of water mist.
After use
Disconnect the lung demand valve: Press the button and simultaneously
pull the lung demand valve out of the facepiece connector.
Remove full face mask: Slide your index fin-
ger under the ends of the neckbands, press
the clamps forwards with your thumbs and
simultaneously pull the full face mask away
from the face over the head.
1 Note the corresponding instructions for use.
3
2
1
4
1)
1)
.
S or phosgene, may be
2

Publicité