10. Technical data

Supply voltage AC/DC
Supply voltage DC
Voltage tolerance
Power consumption
Sensor input
Sensor types
Sensor supply
Switch point for PNP pick-up
Switch point for NPN pick-up
Input frequency, max
Characteristic values
Transmission accuracy
Resolution (internal)
Temperature drift
Reset input 1
External auxiliary voltage
Current consumption
Switch point for PNP circuit
Analogue output
Voltage
Current
Relay output
Switching capacity
Switching time
Cycles
Transistor output
Switching voltage / current
Device data
Housing
Dimensions (H x W x D)
Weight
Protection housing / terminals
Connection
Display
Environmental conditions
Operating / storage temperature
Air pressure / Relative air humidity
Maximum operating altitude
CE mark
page 36
DW2003
110...240 V AC/DC
(50...60 Hz)
27 V DC (typ. 24 V DC)
5 VA
PNP/NPN; NAMUR (24 V DC)
24 V DC; max. 150 mA
short circuit and overload protected
15 kHz (this corresponds to a min. pulse/space duration of 33 µs)
± 0.2% (of the analogue final value)
0...10 V (max. 10.25 V), load min. 10 kOhm
0/4...20 mA (max. 20.5 mA), load max. 500 Ohm
1 changeover contact, floating
6 A (250 V AC); B300, R300
10...20 ms (energising), 30...40 ms (deenergising)
5
3 x 10
(250 V AC, 4 A, ohmic resistance)
PNP switching, externally supplied, short-circuit protected
24 V DC (±20%) / max. 15 mA
housing for DIN rail mounting; plastic
21 dual-chamber terminals; 2 x 2,5 mm² (AWG 14)
LC display, 7/14-segment
-20...+60°C / -25...+80°C
75...106 kPa / max. 75 % (35°C)
according to EN 61010 (1993), +A2 (1995, EMC 89/336/EEC)
EN50081-1; EN 61000-6-2
27 V DC (typ. 24 V DC)
-20...+10 %
24 V DC; max. 15 mA
short circuit and overload protected
> 12 V ON; < 5 V OFF
> 15 V OFF; < 8 V ON
12 bits
< ±100 ppm/K
24 V DC
typ. 2,5 mA
> 14 V
7
> 10
(without load)
78 x 45 x 120 mm
490 g
IP 50/20
2000 m above MSL
DW2004
4 W