Product description

Switch Panel
The switch panel consists according to the
model type of five or seven key buttons.
Power of the supercharger
The first four buttons control the power of
the supercharger.
Button „1"
= low performance of the
supercharger
Button „2"
= middle performance of the
supercharger
Button „3"
= high performance of the
supercharger
Button „Int" = intensive level
Press any button to switch on the extractor
hood. The hood is switched off by pressing
the back-lighted keys once more. The
extractor hood automatically switches back
after 3 min. from the intensive level to level
3 (high performance of the supercharger).
Automatic Cool Down Period
The automatic cool down period is activated
by pressing the button with the clock symbol.
The exhaust hood will progressively switch
from level 3 down to level 1 and run at that
level for approximately 15 minutes before
turning off.
Lighting
Press the button with the light symbol to
turn on the illumination. The illumination is
turned off by pressing the button again. The
illumination is dimmed by pressing and
holding the button for a longer period.
Brightness is raised again by another long
press of the button.
Clean Grease Filter Alert
When the clean grease filter alert lights up
(right button), the filter must be cleaned. Af-
ter cleaning the filter, press and hold the
right button (3) for at least 5 seconds. The
alert light will turn off. The clean grease filter
alert will be activated after a maximum of
15 operating hours or 14 days (even if not-
hing has been cooked
Room ventilation
Pressing the Int button and the clock
symbol button at the same time activates/
deactivates the room ventilation function.
Slider panel control element
The slider panel control element consists
of 4 control panels.
Fan power
Automatic
STOP fan
follow-up time
motor off
Fan power
Touch any field to switch on. The lit field is
touched again to switch off. The fan power is
shown in the left control symbol. Press your finger
onto the symbol area and slowly push to the
right = fan power is increased. All LED bars are
lit = intensive level (switches back by one level
after approx. 5 minute). The more LED bars are
lit, the higher the fan power. Press the LED bar
to the left by touch = the fan power is reduced.
Push the LED bar completely to the left = fan
motor off (LED bar no longer lit).
Automatic follow-up time
By touching the field with the follow-up time
symbol (2nd symbol form the left), the automatic
follow-up time is activated and the follow-up time
symbol lights up. The extractor hood switches
back from level 3 to level 1and runs for approx.
~15 min. there before switching off.
Lighting
the field with the lighting symbol to
Touch
switch on the lighting. The lighting is
switched off by touching again. Touch the
lighting symbol for a longer time = lighting
is dimmed
Display grease filter cleaning
The filter needs cleaning when the filter
cleaning symbol is flashing. Touch the filter
cleaning symbol field for at least 5 seconds
grease filter
cleaning
intensive level