• Replacing the halogen/incandescent lamps (Fig.19):
Only use lamps of the same type and wattage installed on
the device.
• Commands (Fig.20) Mechanical the key symbols are
explained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III.
• Commands Luminous (Fig.21) the key symbols are ex-
plained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes (*).
If your appliance is equipped with the INTENSIVE speed
function, start from level THIRD speed and keeping the but-
ton E pressed for about 2 seconds, this function activates for
about 10 minutes after which it goes back to the previously
set speed.
When the function is active the LED flashes. To interrupt it
before the 10 minutes have expired press key E again.
By pressing key F for two seconds (with the hood switched
off) the "clean air" function is activated. This function switches
the appliance on for ten minutes every hour at the first speed.
As soon as this function is activated the motor starts up at the
first speed for ten minutes, During this time key F and key
C must flash at the same time. After ten minutes the motor
switches off and the LED of key F remains switched on with
a fixed light until the motor starts up again at the first speed
after fifty minutes and keys F and C start to flash again for ten
minutes and so on. By pressing any key for the exclusion of
the hood light the hood will return immediately to its normal
functioning (e.g. if key D is pressed the "clean air" function is
deactivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
(*) The "AUTOMATIC STOP TIMER" delays stopping of the
hood, which will continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
• Active carbon/grease filter saturation:
- When button A flashes at a frequency of 2 seconds, the
grease filters must be washed.
- When button A flashes at a frequency of 0.5 seconds, the
active carbon filters must be replaced or washed depending
on the type of filter.
After the clean filter has been replaced, the electronic memory
must be reset by pressing button A for approximately 5 sec-
onds, until the light on the button stops flashing.
• Commands (Fig.22):
Push-button A = On/Off lights switch.
Push-button B = On/Off cooker hood switch. The appliance
switches on at speed level 1, If the cooker hood is on depress
the push-button for 2 sec. to switch off the cooker hood. If
the cooker hood is at speed level 1 it will not be necessary
to depress the push-button to switch the cooker hood off.
Decreases the motor speed.
Display C = Indicates the motor speed level selected and
activates the timer.
Push-button D = Switches on the cooker hood. Increases the
motor speed. Touching the key at 3rd speed, the intensive
function runs for 10' , then the appliance go back to work at
the original speed. During this function the display blinks.
Key E = The Timer times the functions on activation for 15
minutes, after which they are switched off. The Timer is deac-
tivated by re-pressing Key E. When the Timer is activated the
decimal point must flash on the display. The Timer cannot be
activated if the intensive speed is functioning.
The "clean air" function is activated by pressing key E for 2
seconds when the appliance is switched off. This switches the
motor on for 10 minutes every hour at the first speed. During
functioning a rotary movement of the peripheral segments
must be visualised on the display. When this time has passed
the motor switches off and the fixed letter "C" must be visual-
ised on the display until the motor re-starts after 50 minutes
for another 10 minutes and so on. Press any key apart from
the light keys to return to normal functioning. Press key E to
deactivate the function.
• Active carbon/grease filter saturation:
- When display item C flashes, at a speed where it alternates
with the letter F (e.g. 1 and F), the grease filters must be
washed.
- When display item C flashes, at a speed where it alternates
with the letter A (e.g. 1 and A), the active carbon filters must
be replaced or washed depending on the type of filter.
After the clean filter has been positioned correctly, the
electronic memory must be reset by pressing button A for
approximately 5 seconds, until the indication F or A shown
on the display C stops flashing.
• Mechanical controls (Fig.23): the symbols are as follows:
A= LIGHT / ON-OFF key
B= OFF /FIRST SPEED key
C= SECOND SPEED key
D = THIRD SPEED key
If the hood is shut off at first, second or third speed, when
it is turned back on, it will start at the same speed it was in
when switched off.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE
ABOVE WARNINGS.