tau K892M Notice D'installation page 12

Carte de commande pour un ou deux moteurs monophasés 230vca
Masquer les pouces Voir aussi pour K892M:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1-2
Power input 230Vac, 50Hz, single-phase; 1 = Phase; 2 = Neutral;
3-4
Output for auxiliary courtesy light 230 Vac;
5-6
Flashing light output 230 Vac 20 W max.
7-8
433,92 MHz built-in RX aerial input; 7 = Earth 8 = Signal;
nd
9-10
2
radio channel output;
11-12
24 Vac output for powering safety and/or other devices (photocells, relays for lighting,
etc);
13-15
Pressure-sensitive edge input; 13 = Pressure-sensitive edge; 15 = Common.
If the resistive sensitive edge is not used, do not short circuit terminals 13 and 15. The
input is only excluded by means of dip 9;
Note: if the resistive sensitive edge is used, to install the electric resistance
provided as shown in enclosed instruction.
14-15
Input for pressure-sensitive edge (mechanical edge) or other safety devices, e.g.
photocells (NC contact); 14 = pressure-sensitive edge; 15 = Common;
16-17
Stop push button NC (normally closed) contact. After a stoppage, the system always
starts again with an opening phase and only after receiving a command from the On
button or radio transmitter. 16 = Common; 17 = Stop;
16-18
Input for open/close push button (normally-open contact): for usage, see the functions of
dip switches 2-3; 16 = Common; 18 = Open/close;
19-20-21 Motor (1) output; 19 = Closing phase; 20 = Common; 21 = Opening phase;
22-23-24 Auxiliary motor (2) output; 22 = Closing phase; 23 = Common; 24 = Opening phase;
M5
PIN1 Input for STOP push button
PIN2 Input for OPEN/CLOSE push button
PIN3 Common GND
PIN4 Input for closing limit switch FCC
PIN5 Input for opening limit switch FCA
Note: if the card is fi tted in replacement of an older model (K595M, K696M, K797M or K898M)
there is no M5 terminal block. In its place is a terminal block with 3 screw units that must be
wired as follows:
25-26
Close limit switch input (Normally Closed contact) FCC; 25= Common;
25-27
Open limit switch input (Normally Closed contact) FCA; 25= Common.
12
TERMINAL BOARD CONNECTIONS
K892M