4.19. The air input pipe should not be drained with the risk of affecting the correct operation of the stove. For this
reason, and in order to facilitate fresh air input, it is necessary to set up a ventilation grid AT NOT LESS than
50cm both horizontally and vertically from gas output, see point 4.12.
Direct air currents shall also be avoided as they might prevent a correct operation of the stove and as a
consequence, heat performance.
4.20. In any case the design of the chimney termination will impede the free diffusion in the atmosphere of
combustion products. A metallic mesh with a gap of 3x3 cm can be placed to avoid the entry of birds or
unwanted objects.
COMPLIANCE WITH THESE NORMS ARE OUT OF ECOFOREST'S CONTROL; ECOFOREST DOES NOT BEAR THE
RESPONSIBILITY FOR ANY RESULTING DAMAGE.
WE RECOMMEND THAT A CONFIRMED SPECIALIST SETS UP YOUR PELLETS STOVE.
4.21. Check the space between the stove, the fuel, and any flammable material, check drawing 6, 7, 8 and 9.
4.22. Do not install the stove in a sleeping room.
4.23. The power cable provided by ECOFOREST is 1.4m long; you might need a longer one. Always use a cable with
ground plug.
FREE SPACES AND MINIMUM DISTANCES WITH FLAMMABLE MATERIAL.
Security distances should be respected when the stove is installed in spaces where materials, either
construction materials or those surrounding the stove, are likely to be flammable.
4.24. Install a fire protection between the ground and the stove if the floor is a combustible material.
A
Lateral wall.
Back of the stove. Minimum separation
B
that
allows
visualizing
marking the stove.
C
1.5 x depth of stove.
D
Shelf.
E
Depth of stove.
LOCATION AND SAFETY DISTANCES.
≥ E
the
label
≥ 80 mm
See dimensions
≥ 1000 mm
See dimensions
34
Drawing 7