K factors (in pulse/litre) for screw-ons

When the dimensions of your pipe are slightly different from dimensions d and s given in the table, recalculate the K factor using one
of the formulae in chap. 6.4.2.
If the measuring device does not automatically convert the K factor, use the following conversion formulae before setting the para-
meters of the device:
• K factor in pulse/US gallon = K factor in pulse/litre x 3.785
• K factor in pulse/UK gallon = K factor in pulse/litre x 4.546
Table 22: K factors, external diameters and theoretical cross-sections of screw-ons
measuring device inserted
material of the pipe
dn
100
110
125
150
180
200
250
300
350
400
(L): long sensor version
28
8020, 8024, 8025, 8026
pVc
pp / pe
4,83 (L)
5,29 (L)
3,45 (L)
-
2,55 (L)
3,10 (L)
1,67 (L)
2,12 (L)
1,08 (L)
1,37 (L)
0,80 (L)
1,07 (L)
-
0,63 (L)
-
0,42 (L)
-
0,30 (L)
-
0,23 (L)
English
8041, 8045
pVc
pp / pe
[mm]
33,0 (L)
30,4 (L)
44,7 (L)
-
63,7 (L)
52,1 (L)
137 (L)
78,8 (L)
197 (L)
116 (L)
290 (L)
147 (L)
-
347 (L)
-
510 (L)
-
705 (L)
-
931 (L)
Type S020
Technicaldata
external diameters and theoretical
cross-sections
d
s
d
pVc
pVc
pe/pp
[mm]
[mm]
110
8,1
110
125
9,2
125
140
10,3
140
160
6,2
160
200
9,6
200
225
8,6
225
-
-
280
-
-
315
-
-
355
-
-
400
s
pe/pp
[mm]
10
11,4
12,8
14,6
18,2
20,5
25,5
28,7
32,3
36,4