Position
2
3
4
5
6
7
for the thermostatic valve, the minimum position is
and the maximum
position. The thermostat triggers
the main burner to automatically ignite and turn off (ON /
Off); only the pilot flame remains lit.
Degrees °C
160
170
185
200
215
235
260
290
When the valve knob/tap is turned to the right onto " ", or
the thermostat knob is set to "0", the main burner remains
off.
Turning off the pilot burner
To turn the pilot burner off, press the valve knob/ tap and
turn to position " ".
Emptying the well (fig.8)
The tilting device is designed to simplify the emptying
of the well. The device is activated by means of a hand-
wheel positioned on the right side of the front panel. The
well rises by turning the hand-wheel clockwise and lowers
by turning it anticlockwise. In models with electric
powered tilting, there are buttons instead of the hand-
wheel for raising and lowering the well.