3) Definitions of Outputs
Blinker
Lamp's on/off control. The lamp functions as a warning and optical signaller of potential danger for the gate's motion.
Motor 1
Outputs for the opening/closure control of the motor which drives the first gate wing during the closing phase.
Motor 2
Outputs for the opening/closure control of the motor which drives the gate wing delayed during the closing phase. This wing is usually connected with
an electric lock.

Electric lock

Impulse control for the electric lock release. The output can also control an open gate signalling lamp (see page 24).
4) Definitions of Power Supply Inputs/Outputs
AC IN (FS3 - FS4)
12Vac or 20Vac input for the electronic board power supply.
12Vdc or 24Vdc OUT (It depends on the position of the Jumper JP1)
Power supply output for the photo-cells and/or any other accessory devices.
BATT IN (FS1 - FS2)
Input for a 12Vdc or 24Vdc backup battery connection, it depends on the power supply selected.
Attention: Set up the jumper JP2 in the right position in order to avoid damages of the equipment and/or battery.
5) Definitions of Accessory Inputs/Outputs
Aerial
Input for the connection of an aerial. This input can only be used if a radio receiver card is connected to the unit.
2nd radio channel
Auxiliary control output. To be used only if a two-channel radio receiver card is connected to the unit (J6 connector).
6) Definitions of Optical Signals
DL1 – Programming led (red)
It is lit (together with the blinker) in the programming phase and during the gate's motion.
DL2 – Mains power led (green)
It is lit when the 12Vac or 20Vac voltage is present to the AC IN input.
DL3 – Pedestrian start led (green)
It is lit when the pedestrian start control is operated.
DL4 – Start led (green)
It is lit when the start control is operated.
DL5 – Stop led (red)
It signals the gate's block state. The led goes off when the stop control is operated (emergency).