G) Programming the board
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
Attention : before proceeding with the programming of the card, it is necessary that all the inputs are connected correctly (see chapters D1 and D2).
Radio-command codes self-learning
Press the P1 key once to insert a "Start" code; press the P1 push-button twice to insert a "Pedestrian Start" code. Each time the push-button is
pressed, the led DL1 flashes in acknowledgement. Subsequent pressures of the P1 key must be spaced by 1 sec. minimum periods. When the led is
lit with a fixed light transmit the code to be learn by means of the remote control.
Erasing all stored codes
Press push-button P1 until the led DL1 goes off (about 10 seconds).
Step-by-step logic
Set the dip switches 1 and 2 to OFF
The state of the other dip switches has no effect
Automatic logic
Set the dip switch 1 to OFF
Set the dip switch 2 to ON
The state of the other dip switches has no effect
Condominium logic
Set the dip switch 1 to ON
The state of the other dip switches has no effect
Single wing logic
Set the dip switch 3 to ON
The state of the other dip switches has no effect
Kickback / extra-push logic
Set the dip switch 4 to ON
The state of the other dip switches has no effect
Enable LED lighting
Set the dip switch 10 to ON
The state of the other dip switches has no effect
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
1 2 3 4 5 6 7 8 9 10
ON
OFF
34
ENGLISH
2nd wing delay reset (zero delay)
Set the dip switch 5 to ON
The dip switch 3 must be positioned in OFF
The state of the other dip switches has no effect
Open gate signalling
Set the dip switch 6 to ON
The state of the other dip switches has no effect
Photocell test exclusion
Set the dip switch 7 to ON
The state of the other dip switches has no effect
Motor 1 Amperostop sensibility reduction
Set the dip switch 8 to ON
The state of the other dip switches has no effect
Motor 2 Amperostop sensibility reduction
Set the dip switch 9 to ON
The state of the other dip switches has no effect