Next Systems CTR50 Manuel D'emploi page 25

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
Dip switch 7 (Attention: Dip switch must be positioned obligatorily in ON if the photocells are not used)
It excludes the photocells operation test before the gate departure.
ON= Test OFF
OFF= Test ON
Dip switch 8
It chooses the sensibility of the Motor 1 Amperometric stop.
ON= Low
OFF= High
Dip switch 9
It chooses the sensibility of the Motor 2 Amperometric stop.
ON= Low
OFF= High
Dip switch 10
Enable or disable the operation of the signalling LEDs.
ON= Enable LEDs lighting
Jumper JP2 - Battery charger
In position 1-2 it enables a 12Vdc battery charger. In position 2-3 it enables a 24Vdc battery charger.
Jumper JP1 - Photocells power supply
In position 1-2 it selects 12Vdc as photocells power supply. In position 2-3 it selects 24Vdc as photocells power supply.
JP2 - Battery charger
9) Definitions of Programming Keys
P1 - Allows to insert/cancel the radio-command codes in the memory
P2 - Allows to set the motors' work time and the M2 motor's closing delay time
P3 - Allows to set the pause time
10) Definitions of Protection Fuses
F2 – Battery fuse (10A - Fast)
It disconnects the backup battery from the electronic card in case of short-circuit or electric current consumption anomalies.
OFF= Disable LEDs lighting
3
2
12Vdc
1
3
2
24Vdc
1
JP1 - Photocells power supply
3
2
12Vdc
1
3
2
24Vdc
1