Blinker
The electronic card supplies an on/off control (flashing light) to the lamp. The logic of the blinking allows displaying the gate's operating.
Quick flashing light : it signals the opening phase
Slow flashing light : it signals the closing phase
Fixed light : it signals that the gate is blocked in wait that the obstacle that covers the photocell or photostop to be removed.
The device supplies an on/off control (flashing light) to the lamp for approx. 1 sec. before the motors start (pre-alarm).
Important : In case of absence of power supply, with the backup Battery connected to the card, the blinker flashes every 4 sec. (in opening and
closing cycle).

12) Operation modes

Introduction
The electronic unit contains a micro-processor to control the gate's operation modes. These are the four main operation phases:
Phase preceding the gate's motion
Gate's fast motion phase
Gate's slow motion phase
Gate's pause phase (open gate)
The unit can function in three modes:
Step by step – This mode is enabled by setting the dip switches 1=OFF 2=OFF
Automatic – This mode is enabled by setting the dip switches 1=OFF 2=ON
Condominium– This mode is enabled by setting the dip switches 1=ON 2= No effect
The Condominium mode is the priority operation mode. If more than one modes are selected the priority mode will be enabled.
Notice: The operation logic setting (dip switch), the work time programming and the pause time programming must be carried out only if the cycle is
concluded or before it starts (with closed gate).
The opening and closure cycles are enabled by a Start or Pedestrian start control.
Important : Whatever logic has been selected, the first Start command after the power is supplied to the electronic card will always cause the start of
an opening cycle.
"Step-by-step" mode
After the power is supplied to the electronic card the first start command determines an opening cycle. During the slow-down phase, at the end of the
two work times or after the Limit switches have operated for both motors, the gate stops. The operating cycle is completed (blinker off) and the system
waits for a new start command to determine the closing cycle. If a start command is supplied when the end of travel has not been reached yet the gate
stops. A new start command will cause the reversal of the motion.