8 / MAINTENANCE & SERVICING
PROCEDURE TO ACCES INSIDE THE MACHINE
When the main case is open, motor start-up and blade advancing are disabled by the safety unit.
For all maintenance, adjustment or repair operations, prevent unintentional operation of electrical
and pneumatic circuits on the machine by padlocking the main isolating switch 16 and the valve 14
(page 11).
8.A.a Opening the main case
Press button 2 on the control panel (page 28) if necessary.
Position the control panel key 3 (to "unlock cover", wait during the 30 second time-out until green lamp V1 (page 28) goes out,
indicating that the blades have stopped completely.
Left table side
Release
the
left
spring clips, SG.
Figure 8-1
Open the main case
to
its
highest
position.
Using
cover handle, pivot
the cover upwards
and let it rest on the
flexible stud at the
top of the machine.
Figure 8-3
To close the main case, do the reverse operation.
8.A.b Removing the blades
Open the main case (see above).
SG
During this operation, gloves should be worn to handle the blades and avoid
getting your hands cut.
Right table side
Release the right
spring clips, SD
Figure 8-2
CS969
SD