USER MANUAL
ASPIRATION
To conform to hygiene standards, the machine must be connected to an extraction air intake producing a minimum
flow rate of 2500m3/hour. The circuit comprises two intake ports 120 mm in diameter: both at the rear side (both plug
must be connected. This installation guarantees effective extraction and must never be dismantled or modified. ( See
page : 11, description Rep : 18.)
-
Using of FUSES KIT 12A and 16A.
C
: 3 x Fuse : See below
In case of use of the electrical outlet
to replace the 3 fuses of switches
For a CS969 400 V Three-phase, (12 A).
For a CS969 230 V Three-phase, (16 A).
Figure 6-20
A
Figure 6-21
17
for power supply an extractor on the machine , it will be necessary
A
;by those contained in pocket
17
C
CS969
Figure 6-22
26