Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Damage to hearing if no suitable ear protec-
tion is used.
2. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
Warning! This equipment generates an electro-
magnetic Þ eld during operation. Under certain
circumstances this Þ eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Always pull the power plug before making
adjustments to the equipment.
The scariÞ er is delivered unassembled. The grass
basket and the complete push bar must be as-
sembled and mounted before using the scariÞ er.
Follow the operating instructions step-by-step
and use the pictures provided as a visual guide to
easily assemble the machine.
Fitting the rear wheels (see Fig. 3 and Fig. 4)
Insert the axles of the rear wheels into the
openings provided (Fig. 3 / Item A).
Secure the wheels with the screws provided .
(Fig. 4/ Item 19)
Anl_GE_SA_1640_SPK7.indb 22
GB
Fitting the push bar brackets (see Figs. 5
and 6)
Remove the quick-release lever (Fig. 5/
Item 13) and the washer (Fig. 5/Item 17)
Connect the push bar bracket (Fig. 5/Item 7)
to the fastening screw. Make sure that the
curve in the tube (Fig. 6/Item A) is on the
outside.
Now put the washer back on and tighten with
the quick-release lever.
Important. The same tilt angle must be set for
both push bar brackets!
Fitting the lower push bar (see Fig. 7)
Slide the lower push bar (Fig. 7/Item 6) onto
the push bar brackets. Do not forget to slip
the stress-relief clip (Fig. 7/Item 4) onto the
tube first.
Now join the tubes together using the screws
(Fig. 7/Item 18), washers (Fig. 7/Item 17) and
quick-release levers (Fig. 7/Item 13) supplied.
Fitting the upper push bar (see Fig. 8 to
Fig. 10)
Position the upper push bar (Fig. 8 / Item 5)
such that its holes line up with the holes of the
lower bar.
Now join the tubes together using the screws
(Fig. 8/Item 18), washers (Fig. 8/Item 17) and
quick-release levers (Fig. 8/Item 13) supplied.
Use the cable clips (Fig. 9/Item 12) to attach
the power cable to the tubes of the push bars
so that it is possible to open and shut the
ejector flap (Fig. 10/Item 12).
Important!
Please ensure that the ejector ß ap can be opened
and closed easily!
Assembling the grass basket (see Figs. 11-
14)
Push both frame parts into each other (Fig.
11).
Pull the grass basket over the metal frame
(Fig. 12).
Pull the rubber clips over the metal frame
(Fig. 13).
To hang the grass basket on the scarifier you
must lift the ejector flap (Fig. 14/Item 10) with
one hand and with the other hand take hold of
the grass bag by the handle and hook it onto
the scarifier from above (Fig. 14).
- 22 -