RMV5301, RMV5305
Item
Description
11
Gas valve
12
DC power outlet
13
Gas valve supply line
A
Optional connections to DC power outlet
B
Negative terminal (–) DC permanent supply for electronics
C
Positive terminal (+) DC permanent supply for electronics
D
Connection D+ (only for RMV5305)
E
Connection S+ (only for RMV5305)
F
Positive cable of the heating cartridge
G
Earth cable of the heating cartridge
AC power
➤ Connect the refrigerator with the mains plug to an AC socket.
DC power
Please note the following cable sizes:
– < 6 m (interior): 4 mm
– > 6 m (interior): 6 mm
– Connections D+ and S+: 1 mm
– Cable fed via drawbar (caravans only): 2.5 mm
➤ Secure the power supply line to the heating element (connections F and G) with
a 15 A fuse and the line to lighting/electronics (connections B and C) with a 2 A
fuse.
➤ Connect the heating element (connections F and G) with the shortest possible
cable.
➤ Run the power supply line to the heating element (connections F and G) via a
relay controlled by an ignition lock to prevent the vehicle battery from completely
discharging if the engine is switched off accidentally (fig. f, page 11).
➤ Connect a DC permanent supply to the connection for lighting/electronics
(connections B and C).