6.3
Creating the air vents
I
NOTE
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been
provided.
➤ Make an air inlet vent and an air outlet vent in the outer wall with the size of
451 mm x 156 mm. When doing so, observe the information, see chapter "Pre-
paring the installation" on page 19.
If the ventilation grille of the air inlet vent cannot be installed flush with the floor of the
niche, you need to install an inlet vent in the floor:
➤ Make an air inlet vent in the floor (fig. 2 4, page 4) behind the refrigerator near
the gas burner with a diameter of at least 40 mm. The vent pipe must lead directly
outside. This allows leaking unburned gas to escape outside.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt from get-
ting inside while driving (fig. 4, page 5).