System Specifications - onsen ON-I14L-LP Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SYSTEM SPECIFICATIONS

MODEL NO.
Type of appliance
Flue system
Rated gas pressure
Temperature range
Dimensions (mm)
Weight
Connections
Ignition system
Max/min gas consumption
Minimum operating water flow
Minimum operating pressure
Power supply
Safety devices
Electrical consumption (normal)
onsenproducts.com
onsenproducts.ca
Natural gas
Propane (LPG)
Width
Height
Depth
Gas
Cold water supply
Hot water supply
Natural gas
Propane (LPG)
Flame failure
Boil dry
Over temperature
Fusible link
Pressure relief valve
Combustion fan rpm check
Over current
800-996-5559
ON-I14L
Temperature controlled continuous flow gas hot water unit
Room sealed-forced draught flue
10.5 inch W.C. (2610 Pa)
13.0 inch W.C. (3230 Pa)
Within 35° C to 60° C (95° F to 140° F)
13.9 in. / 353 mm
25.94 in. / 659 mm
5.59 in. / 142 mm
32 lbs / 14.5 kg
½ inch NPT
½ inch NPT
½ inch NPT
Electronic ignition
100,000 Btu/h - 20,000 Btu/h
97,000 Btu/h - 20,000 Btu/h
0.67 gpm (2.5 l/min)
15 PSI
120 Vac/60Hz/1A, one phase
Flame rod
Water flow sensor /221° F thermistor
185° F (integrated circuit system)
320° F Thermal fuse
Opens 125 PSI
Integrated circuit system
Glass fuse (5 Amp/5 Amp)
30 W