What's Included In The Box - onsen ON-I14L-LP Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The appliance must be electrically grounded in accordance with local codes. In the event there are no local
codes, the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1 shall prevail.
The gas pressure must be between these values: 3.5" W.C. (870 Pa) and 10.5" W.C. (2610 Pa) for natural gas
and 8.0" W.C. (1990 Pa) 13.0" W.C. (3230 Pa) for liquid propane. The gas pressure must not exceed these limits.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi
(3.5 kPa).
The appliance should be located in an area where leakage of the tank or connections will not result in damage
to the area adjacent to the appliance or to lower floors of the structure. When such locations cannot be
avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance.
The pan must not restrict combustion air flow.
Do not obstruct the combustion air intake or heater exhaust and ensure air intake is not near an area that will
allow chemical fumes to enter the combustion air system.
Do not use to heat pools or spas (hot tubs) that use chemically treated water.
If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the
cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or
local plumbing inspector on how to control this situation.

WHAT'S INCLUDED IN THE BOX

The following contents are included. If any items are missing, please contact Onsen.
ITEM
Water heater
Installation and Operation Manual
Pressure relief valve
Pipe reducer
onsenproducts.com
20
onsenproducts.ca
QUANTITY
1
1
1
2
800-996-5559
support@onsenproducts.com

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour onsen ON-I14L-LP

Ce manuel est également adapté pour:

On-i14l-ng

Table des Matières