ROUTINE INSPECTION CHECKLIST
Any flammable materials in the vicinity of the water heater or exhaust piping?
Any unusual noises coming from the heater while in operation?
Are the air intake and exhaust free from any blockage or foreign objects?
Any signs of water leaking near heater or pipes?
Any abnormal appearance to unit casing?

MAINTENANCE CHECKLIST

Clean outside of unit and control panel:
Use a wet cloth to remove any surface dirt. Use a dry cloth to wipe it dry.
A very mild detergent may be used if unit is very dirty.
Never use any petroleum based cleaners or solvents as these can damage the panel.
Check and clear air intake of any debris that might impede air flow.
Clean inlet water screen.
Examine venting system.
Clean inside of unit by vacuuming or blowing out dust that collects in the unit. Do not open the burner.
PLEASE NOTE THAT THIS CLEANING SHOULD ONLY BE DONE BY AUTHORIZED SERVICE PERSONNEL.
Visual flame inspection.
Lime scale cleaning (if required).

MAINTENANCE PROCEDURES

Burner Inspection and Cleaning
1
The burner should flame evenly over the entire surface of the burner head when operating correctly.
2
The flame should burn with a clear, blue, stable flame.
3
Presence of a yellow flame or of black deposits on the burner head indicates cleaning and/or burner
replacement should occur.

Fan Maintenance

1
The fan motor is permanently lubricated and does not require periodic lubrication.
2
If the motor fails, it must be replaced by a qualified technician only.