EXHAUST VENT PIPE ASSEMBLY
1
An 80 mm (3.15 in.) to 75 mm (3 in.) pipe reducer is included with this water heater to allow connection of
a 3 in. vent pipe.
2
Use the Universal Adapter pipe provided by the vent manufacturer to connect the vent pipe to the unit.
3
Follow the manufacturer vent pipe assembly guidelines and sample diagrams below.
4
Please use UL certified stainless steel vent pipe as per the standard UL 1738 and ULC S636-BH.
Ref
A =
Clearance above grade, veranda, porch, deck, or balcony
B =
Clearance to window or door that may be opened
C =
Clearance to permanently closed window
Vertical clearance to ventilated soffit located above the terminal within a
D =
horizontal distance of 2 ft (61 cm) from the center line of the terminal
E =
Clearance to unventilated soffit
F =
Clearance to outside corner
G =
Clearance to inside corner
Clearance to each side of the center line extended above meter/regulator
H =
assembly
I =
Clearance to service regulator vent outlet
onsenproducts.com
26
onsenproducts.ca
Inside
corner detail
Fixed
closed
Operable
Clearance Description
800-996-5559
LEGEND
V
= Vent terminal
X
= Air supply inlet
= Area where terminal is not permitted
Fixed
closed
Operable
Canadian Installations (1)
12 in (30 cm)
12 in (30 cm)
*
*
*
*
*
3 ft (91 cm) within a height of
15 ft (4.6 m)
3 ft (91 cm)
US Installations (2)
12 in (30 cm)
12 in (30 cm)
*
*
*
*
*
*
*