Ref
Clearance to non-mechanical air supply inlet to building or the combustion air
J =
inlet to any other appliance
K =
Clearance to a mechanical air supply inlet
L =
Clearance above paved sidewalk or paved driveway located on public property
M =
Clearance under veranda, porch, deck, or balcony
* Refer to ANSI Z223.1/NFPA 54 or CSA B149.1, for clearances not specified in these requirements, one of the
following shall be indicated:
i) The minimum distance from adjacent public walkways, adjacent buildings, openable windows, and building
openings shall not be less than those values specified in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, and/or
the Natural Gas and Propane Installation Code, CSA B149.1;
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Notes:
1
In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code.
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
3
If locally adopted installation codes specify clearances different than those illustrated, then the most stringent
clearance shall prevail.
Termination Details
1
Determine the number of elbows of 90 degrees that will be used in the evacuation system (two elbows of
45 degrees being considered as a single elbow of 90 degrees).
2
Refer to the table below to determine the maximum length in function of the number of elbows.
For example: If you have only one elbow, the maximum length will be 10.7 m (35 ft).
0
1
41 ft (12.5 m)
35 ft (10.7 m)
Termination Configuration
VERTICAL TERMINATIONS
The air intake requires a return bend or two 90º elbows to prevent entry of rain.
The vent termination and air intake must be in the same pressure zone.
onsenproducts.com
onsenproducts.ca
Clearance Description
NUMBER OF ELBOWS OF 90º
2
29 ft (8.8 m)
23 ft (7.0 m)
800-996-5559
Canadian Installations (1)
12 in (30 cm)
6 ft (1.83 m)
7 ft (2.13 m) †
12 in (30 cm) ‡
3
4
17 ft (5.2 m)
ENGLISH
US Installations (2)
12 in (30 cm)
3 ft (91 cm) above if within
10 ft (3 m) horizontally
7 ft (2.13 m) *
*
5
6
11 ft (3.4 m)
5 ft (1.5 m)