F a u l t D i a g n o s i s
S y m p t o m , P o s s i b l e C a u s e a n d R e m e d y
S Y M P T O M
P O S S I B L E C A U S E
Pneumatic motor
Air leak from motor
runs slowly
Low air pressure
Air way blockage
Worn drive screw
Rotor blades jamming
Rotor blades worn
Insert does not
Stroke incorrectly set
deform properly
Air pressure outside the tolerance
Low oil level
Insert out of grip
Drive screw turns
Worn or damaged drive shaft
independent of
Worn or damaged drive screw
motor
Adaptor nut loose
Insert will not
Incorrect insert thread size
place onto
Incorrect drive screw fitted
drive screw
Worn or damaged drive screw
Nose equipment incorrectly assembled
Tool is jammed on
Excessive stroke
placed insert
Defective insert
Worn or defective drive screw
Drive screw breaks
Stroke of tool excessive
Side load on drive screw
Tool does not spin
Screw adaptor nut loose
on
No air supply
Item numbers in bold refer to the Base Tool General Assembly drawing and Parts List pages 16-17.
Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.
R E M E D Y
Check for worn seals. Replace.
Increase
Clear restriction in air supply
Replace
Lubricate tool through air inlet
Replace rotor blades
Adjust
Adjust
Prime tool
Check grip range of insert
Replace
Replace
Tighten
Change to correct insert
Change to correct drive screw
Replace
Disconnect air supply, re-fit nose equipment
carefully
DO NOT DEPRESS TRIGGER. Depress
emergency spin-off button. Tool should spin
off. Reset stroke. If not, disconnect air to tool.
Insert a 4 mm pin through nose casing slots
into Spindle 43. Turn until drive screw leaves
insert. Use new insert AND drive screw.
Reset stroke
Hold tool square to application when placing
Insert
Tighten
Connect
PA G E R E F
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
23