Error Messages; Charging Characteristics - EUFAB 16647 Manuel De L'opérateur

Chargeur de batterie intelligent 6/12 v 4 a également pour les batteries au lithium
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18

6.4.3 ERROR MESSAGES

No battery connected, battery connected incorrectly, battery voltage does not match the
charging programme set, overheating.
Connect the battery correctly, select the appropriate charging programme, disconnect the
charger from the battery, let it cool down.
Error message in 6 V mode. The battery voltage is below 5.5 V, after a charging time of
5 hours the battery voltage is below 6 V. The battery is probably defective, have the
battery checked.

6.4.4 CHARGING CHARACTERISTICS

The automatic charging process for lead-acid batteries (wet AGM or gel batteries) follows a 9-stage characteristic
curve in order to charge the battery gently and optimally, see Fig. 3.
Figure 3: Charging characteristic for lead-acid battery
For lithium batteries, the charger uses a 7-step characteristic curve that is adapted to the characteristics of this battery
type, see Fig. 4
Figure 4: Charging characteristic for lithium battery