2.2 Battery charge state display
The lEDs (17) indicate the residual charge state of the battery. The green lEDs light when the
battery has been 100 % charged, and also during flashing with the unit.
An orange lED warns before the charge state of the battery becomes too low. As soon as this
appears, the remaining charge state is 0 %. if the battery voltage sinks too low, the control
display (7) shows the signal „A". The unit remains blocked for further releases until the battery
is recharged or replaced with a full one.

3. mOdeLLing Light

The output of the modelling light cannot be set proportionally to the flash intensity and always
corresponds to the full power output ratings on full power of the connected halogen lamp.

3.1 Battery operation

The "mod" key (14) switches the modelling lamps on or off for all connected lamps. When switched
on, the green lED lights up. With regard to the control of the modelling light this power pack has
an automatic switch-off during battery-powered operation. if the "mod" key is pressed again within
1,5 s after activating the modelling light, the switch-on time will be extended, with each pressure
of the key, by a further 0 s. by pressing the "mod" key, once only, to activate the modelling light,
the switch-on time is 0 s. if the key is pressed 4 times consecutively the maximum switch-on time
of 80 s is attained. An audible signal sounds with each pressure of the key. This function ensures a
prolonged battery service life.
Specially for mobile work with this battery-operated power pack broncolor offers the Mobilite 
small lamp, with built-in reflector and modelling light 1 V / 100 W and own accessories with small
dimensions. The lamp has an automatic thermal protection to prevent overheating and an addi-
tional switch for the modelling light. The switch on the lamp permits selective lighting control with
the modelling light.
The Mobil Ar power pack can also be used with conventional broncolor studio lamps (Picolite,
Pulso and Unilite lamps). The modelling light cannot be used.