10. Lamps
10.2 replacing flash tubes and halogen lamps
Prior to any change of the flash tube or halogen lamp bulb, the lamp must be disconnected from
the power pack! Halogen lamps and flash tubes can be plugged in.
To change the flash tube and halogen lamp release the spring ring and remove the protecting
glass. The flash tube must be pulled out straight along the lamp base axis. When inserting the
tube be sure that it is fully pushed in.
Taking the lifespan into consideration, the halogen lamp should not be handled with bare hands.
Finally, replace the protecting glass and fasten with the spring ring. The protecting glass is available
in the versions "UVE" art. no. 4..55 (5500 K) and "UVE matt" art. no. 4.5.55 (5500 K).
10.3 Lamp plugs
The lamp plugs and sockets carry mechanical interlocks to prevent inadvertent disconnection.
To unplug, push down the locking spring below the cable guide and lift out the plug.
10.4 extension cable for mobilite
The extension cable (,5 m), available as accessory with the article no. 4.150.00, is especially thin
and flexible. it can only be used with the Mobilite and Mobilite . Should this cable be used with
other lamps the modelling light and fan will not function.
10.5 Lamp fuses
only sand-filled fuses of the type indicated on the type plate may be used; otherwise the halogen
lamp may explode.

11. speciaL features

11.1 cooling fan
The cooling fan of the power pack Mobil Ar operates for 0 minutes after switch off, this guaran-
tees correct cooling down of the electronics.