VOLTCRAFT LSG-4 Mode D'emploi page 41

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Resistance Ω
5
Range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Overload protection 600 V
Diode test
6
Test voltage
1.5 V
Overload protection 600 V
Acoustic continuity tester
7
< 35 Ω permanent sound, overload protection 600 V
Do not exceed the maximum permitted input values. Never touch circuits or parts of circuits with voltages
of more than 25 V/ACrms or 35 V/DC! Mortal danger!
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Resolution
0.001 V
Accuracy
±(1.0 % + 6)
±(1.5 % + 4)
±(2.0 % + 5)
±(5.0 % + 8)
Test current
1 mA (typical)
41

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2181313

Table des Matières