Issue: Wires are damaged
• Document the damage and request new AC cable, handset,
or leg as required.
Issue: Handset and control box are not working
• Unplug everything from control box for 10 seconds, then plug back in.
Perform re-sync ( see page 15 ).
• If it lights up green, this means there is power going to the table.
If not, request a new control box.
• Does the handset light up and display correctly?
If not, request a new handset.
Perform re-sync ( see page 15 ).
• If the frame still does not adjust, a service technician needs to be called.
Issue: Legs are not moving together
• Have a service technician bring in a new control box
to test on the frame.
• If the test control box does not fix the issue, the service technician
should have spare legs to test and replace the problem leg( s ).
Issue: Frame is leaking lubricant from
the bottom of a leg
• The frame may have been over-lubricated and the extra lubrication
is now leaking out.
This will not cause any mechanical problems with the frame
and it will continue to work properly.
• Wipe off any excess lubrication and the frame should no longer leak.
Issue: Mid-section of leg does not adjust
with whole leg
• The leg will continue to work properly. May make a loud noise
while adjusting.
• If this is a persistent issue, a service technician can replace the leg.