6. INSTRUCTIONS FOR USE
6.1. Start-up
Fill tank with clean fuel. Only use Diesel or Kerosene.
The fuel gauge on top of the tank allows to check fuel level
Connect the power cord plug to a 230 V 50 Hz earthed electrical supply system.
Earthing is mandatory.
Models CAC20KW / CAC30KW / CAC50KW :
When complete "start-up" above, the power indicator will light, the display window
will show the ambient temperature value.
Push the power switch to "on" position.
If the thermostat control knob setting temperature is higher than the ambient
temperature, the electrodes start sparking and after 7 seconds, the heater starts.
If the thermostat control knob setting temperature is lower than the ambient, turn
thermostat control knob to desired temperature setting, the electrodes start sparking
and after 7 seconds, the heater starts.
COLD START-UP: at low temperature keep the air vent hole (see Fig. 6) closed by a
finger during ignition to make start-up easier.
ABNORMAL OPERATION: in case of malfunction (flame failure, reduced air flow, bad
combustion, etc.) the heater stops and the indicator light starts FLASHING (THE
LOCK-OUT MODE code will be showed on the display window).
6.2. Manual reset/restart
If the heater is in lock-out mode, check and remove the cause of lock-out before
restarting the heater. To reset, turn the ON/OFF switch to 0 and then again to I. In
case of repeated malfunction, call technical service. Turning the thermostat control
knob will NOT reset the heater.
6.3. Shut-down
Move switch to "OFF" (O) position. Unplug the unit when not used for a long time.
Never disconnect the heater from mains to stop it while in
operation. Always allow the cooling sequence to be completed