MFP 051E, MFP 101E, MFP 151E, MFP 201E
2.1. Wall mounting
ATTENTION!
The original wall bracket supplied on the rear
of the device must be used.
Release the attachment screws on the rear of the
device and remove the wall bracket. To do this,
turn the plastic part (1) clockwise by a quarter
turn.
Attach the wall bracket to the wall with at least four
screws (diameter max. 5.5 mm).
Place the device on the lower tabs of the wall
bracket and hook in at the top.
Tighten the attachment screws on the rear again.
NOTE
There are two safety chains on the rear which ensure
that the device is held by the wall bracket, in case
there is a problem with hooking in the device. The de-
vice is attached to the wall bracket by means of hook-
ing the hook into the hole (2).
1
2
Model
MFP 051E MFP 101E MFP 151E MFP 201E
Dim. A
564
Dim. B
240
Dim. C
254
Dim. D
162
All dimensions in mm.
3.
Electrical connection
The voltage specified on the type plate must match
the line voltage.
The cable must not be in contact with the casing.
It is recommended that a separate electric circuit be
provided for the power supply.
www.dimplex.eu
860
1020
1254
350
500
700
398
398
398
255
260
277
The device must only be repaired by a qualified elec-
trician in accordance with the applicable safety regu-
lations. Heating device must be earthed!
Connection may only take place on securely routed
cables!
A disconnecting device with a contact opening of at
least 3 mm at each pole (e.g. circuit breaker) must be
provided in the permanently installed wiring.
3.1. Connection options
If a central temperature reduction is to take place via
the pilot wire, device connection A should be used, if
not, device connection B.
If the black wire is not used, it must be connected to
an electrically insulated terminal and not to the power
supply.
Under no circumstances may the black wire be con-
nected to a ground connection or to the green/yellow
wire.
3.2. Commands via the pilot wire
Command
Signal
Comfort
Eco
Frost protection
Heating off
NOTE
In manual mode, the commands "frost protection"
and "heating off" have priority. This is indicated by the
word AUTO flashing.
NOTE
The commands "frost protection" and "heating off"
switch the blower off.
2508/B
English
Measurement against neutral
0 Volt
230 V
115 V (negative)
115 V (positive)