Mounting Instructions - Dimplex FW 550S Instructions De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

FW 550S
ATTENTION!
Device not attached near curtains, draperies
and other flammable materials!
2. Wall Mounting
The device plug must be accessible after installation.
The heating device must be aligned horizontally and in-
stalled on a vertical wall (see illustration).
100
Fig. 1: Minimum clearance
Make sure that the inflow and outflow of air at the top
and bottom of the device are unimpeded
In addition, a minimum clearance of 500 mm between
inflammable objects e.g. curtains, towels or heat-sensi-
tive plastics and the front of the unit must be main-
tained.
Installation below a wall socket is not permissible.
Minimum clearances must be observed.
It is not permissible to install the device in protection
zones as defined in current regulations.

2.1 Mounting Instructions

NOTE
NOTE
Use the original wall bracket supplied!
Drill the mounting holes and insert dowels.
Screw the wall bracket into place.
Fig. 2: Drill dimension
EN-6
300
200
.
FW_550S_dimplex_gb · 08/51081/0 – Issue 4
Hang the heating device in place.
Screw the heating device into place on both sides
of the wall bracket.
Fig. 3:
3. Electrical Connection
The voltage specified on the type plate must match the
present mains voltage.
If the power line of this device is damaged, it must be
replaced by the manufacturer or after-sales service, or
else by a similarly qualified person, in order to prevent
risks.
The device plug must always be accessible.
To prevent danger by accidental resetting of the ther-
mal tripping unit, this device must not be supplied via
external switching devices (e.g. timers) or connected to
a circuit that is regularly switched on and off by the util-
ity company.
4. Operation
The room temperature is regulated using the infinitely
adjustable thermostat (A).
If the rotary knob is set to the lowest setting i.e. to the
extreme left, the thermostat switches the heating de-
vice on at an ambient temperature of approx. 10° C.
When the thermostat switches on, the red lamp lights
up (B).
Fig. 4: Operation elements
B
A
www.dimplex.de/en